=====Adding Luns===== I have not tried this procedure I ussually recommend rebooting server Adding a LUN To add a new LUN to an existing PowerPath configuration: - Ordered List ItemScan the bus for the LUNs. - Ensure that the new LUN is created on the storage side and recognized by Linux. On SLES 10 SP4 , SLES 11 SP2, SLES 11 SP3, RHEL 5.x, RHEL 6.x, OL 5.x and OL 6.x. For example, if powermt display lists HBAs 8 and 9, initiate the scan by typing: echo “- - -“ > /sys/class/scsi_host/host8/scan echo “- - -“ > /sys/class/scsi_host/host9/scan For iSCSI software initiator, type: echo “- - -“ > /sys/class/scsi_host/host/scan - Run powermt config to configure the new LUN. - Run powermt display to confirm the addition of the new LUN. or you can use echo "1" > /sys/class/fc_host/host1/issue_lip which requests a lip